Remedy for misalignment of hemispherical head of bilobe cargo tank in liquefied petroleum gas carrier (CROSBI ID 161816)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Senjanović Ivo ; Rudan, Smiljko ; Ljuština, Ana Maria Remedy for misalignment of hemispherical head of bilobe cargo tank in liquefied petroleum gas carrier // International shipbuilding progress, 55 (2008), 4; 253-279

Podaci o odgovornosti

Senjanović Ivo ; Rudan, Smiljko ; Ljuština, Ana Maria

engleski

Remedy for misalignment of hemispherical head of bilobe cargo tank in liquefied petroleum gas carrier

This work describes the remedy for a misalignment at the joint of two segments of hemispherical heads in a bilobe cargo tank. The misalignment is the result of a relatively thin spherical shell and production difficulties. Measurements of out-of-roundness show a rather large deviation of meridional camber and variation of radius in the head cross-section plane. At the ends of the segments the spherical form changes into a conical one. As a result a peak occurs in the meridional generatrix, which causes high stress concentration. The cross-section of the hemisphere at the segment joint is reinforced with a ring in order to overtake the bending moment caused by the variation of circular radius. The ring dimensions are determined based on an approximate consideration. Stress concentration at the segment joint is reduced by two additional rings connected with a set of bars in the meridional direction. Angular distance between the bars is specified in such a way that the strength criteria, i.e. stress and fatigue requirements according to the Classification Rules, are satisfied. Stress distribution in the actual imperfect and reinforced structure is determined by the finite element method. Total static plus dynamic tank pressure is taken into account.

LPG carrier ; bilobe tank ; hemispherical head ; misalignment ; reinforcement ; strength ; fatigue ; finite element method

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

55 (4)

2008.

253-279

objavljeno

0020-868X

Povezanost rada

Brodogradnja

Indeksiranost