FMEA Analysis of Xeikon Electrophotographics (CROSBI ID 40278)
Prilog u knjizi | izvorni znanstveni rad
Podaci o odgovornosti
Plehati, Silvio ; Pavlović, Tomislav ; Bogović, Tomislav ; Pap, Klaudio ; Žiljak-Vujić, Jana
engleski
FMEA Analysis of Xeikon Electrophotographics
By introducing FMEA analysis of Xeikon DCP32D electrophotographic printing model it is shown which components of the machine are weakest link in the printing. Each component is shown separately according to the modules and units of the machine, so that the critical component of each module can be read. By observing the critical component we can improve printing results and minimize cost of production. Solution is in improving critical component and suggestion is to evaluate and validate this component using FMEA analysis.
Xeikon FMEA, Xeikon electrophotographic model, failures in digital printing, corona wire failure, scorotron failure
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
977-984.
objavljeno
Podaci o knjizi
DAAAM International Scientific Book 2009
Katalinić, B.
Beč: DAAAM International Vienna
2009.