Napredna pretraga

Pregled bibliografske jedinice broj: 408219

Temperature Distribution Measurement in an Axially Symmetric Source which is not Optically Thin


Skenderović, Hrvoje; Vujnović Vladis; Demoli, Nazif; Rukavina, Jadranka
Temperature Distribution Measurement in an Axially Symmetric Source which is not Optically Thin // Fizika A, 3 (1994), 127-140 (podatak o recenziji nije dostupan, članak, znanstveni)


Naslov
Temperature Distribution Measurement in an Axially Symmetric Source which is not Optically Thin

Autori
Skenderović, Hrvoje ; Vujnović Vladis ; Demoli, Nazif ; Rukavina, Jadranka

Izvornik
Fizika A (1330-0008) 3 (1994); 127-140

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Electic discharge; temperature measurement; mercury lamp

Sažetak
We elaborated two spectroscopic methods for the temperature distribution in axially symmetric source. One method uses the self-reversed spectral line ; this method is based on a comparison of the measured absolute maximum (peak) intensity with that calculated as a function of axial temperature. Another method which uses a spectral line without self-reversal, was based on the Kirchhoff's law and exploits two-path absorption technique and Abel transformation. For both methods, knowledge of atomic broadening constants and transition probabilities is not crucial.