Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Exercise induced von Willebrand Factor release - New model for routine endothelial testing (CROSBI ID 148347)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Balen, Sanja ; Ružić, Alen ; Mirat, Jure ; Peršić, Viktor Exercise induced von Willebrand Factor release - New model for routine endothelial testing // Medical hypotheses, 69 (2007), 6; 1320-1322. doi: 10.1016/j.mehy.2007.03.011

Podaci o odgovornosti

Balen, Sanja ; Ružić, Alen ; Mirat, Jure ; Peršić, Viktor

engleski

Exercise induced von Willebrand Factor release - New model for routine endothelial testing

Endothelial dysfunction (ED) is actively involved in the mechanism of occurrence, development and progression of all the degrees of atherosclerosis. The established impact of ED on the progress and outcome of cardiovascular diseases, together with convincing indications of a possible successful therapeutic modification, necessitate the changeover of ED assessment from experimental to a routine practice. As there is no appropriate method for a clinical practice, scientists anticipate significant research efforts in the further development. Among numerous methods already available, von Willebrand Factor (vWF) stands out significantly. In accordance with the accepted leading diagnostic role of vWF baseline levels in the group of peripheral endothelial markers, and earlier scientific observations on the absence of its expected reactivation during physical exercise, we hypothesised this promising theory. We believe that a constant stronger release of vWF in endothelial cell injury leads to the exhaustion of its stores in Weibel– Palade bodies with the consequent absence of the expected rise of concentration during the exercise. Therefore, we hypothesised that ED could be exhaustible vWF endothelopathy and the exercise induced release of vWF a new, simple, safe and reliable test for the detection of ED and monitoring of the expected therapeutic effect. In order to have a final clinical usability of the proposed diagnostic model, it is necessary to test its reliability in different pathological and risk states, and establish susceptibility in therapeutic procedures. The correlation with invasive functional angiographic tests and the flow mediated dilatation test of peripheral arteries also needs to be validated. We expect the proposed test of vWF inducibility to find its place in clinical practice, i.e. in prevention, prediction and therapy of cardiovascular diseases.

endothelial dysfunction; von Willebrand factor; exercise testing

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

69 (6)

2007.

1320-1322

objavljeno

0306-9877

10.1016/j.mehy.2007.03.011

Povezanost rada

Temeljne medicinske znanosti, Kliničke medicinske znanosti

Poveznice
Indeksiranost