Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Can ultrasound be useful for predicting the size of a left double-lumen bronchial tube? Tracheal width as measured by ultrasonography versus computed tomography. (CROSBI ID 148179)

Prilog u časopisu | stručni rad

Šustić, Alan ; Miletić, Damir ; Protić, Alen ; Ivančić, Aldo ; Cicvarić, Tedi Can ultrasound be useful for predicting the size of a left double-lumen bronchial tube? Tracheal width as measured by ultrasonography versus computed tomography. // Journal of clinical anesthesia, 20 (2008), 4; 247-252

Podaci o odgovornosti

Šustić, Alan ; Miletić, Damir ; Protić, Alen ; Ivančić, Aldo ; Cicvarić, Tedi

engleski

Can ultrasound be useful for predicting the size of a left double-lumen bronchial tube? Tracheal width as measured by ultrasonography versus computed tomography.

Study Objective: To correlate tracheal width as measured by ultrasound with width measured by computed tomography (CT), and to evaluate the possible role of ultrasound in the selection of the proper size of left-sided double-lumen endotracheal tubes (LDLTs). Design: Two independent, prospective, observational clinical studies (Study 1 and Study 2). Setting: University hospital. Patients: Study 1 included 25 patients and Study 2 included 20 adult thoracic surgery patients who required a LDLT during anesthesia. Interventions and Measurements: In Study 1, CT measurements of tracheal width were made at the coronary plane 0.5 cm above the sternoclavicular joint ; CT measurements of the left main bronchus diameter were made 1 cm below the carina. Ultrasound measurement of tracheal width was performed just above the sternoclavicular joint in the transversal section. In Study 2, patients' tracheas were intubated with a LDLT based on ultrasound measurements. The frequencies of incorrect selections of LDLT and unsatisfactory lung collapse were analyzed. Main Results: There was a strong correlation between tracheal width as measured by ultrasound and tracheal width (r=0.882, P<0.001) and left main bronchus width (r=0.832, P<0.001) as measured by CT. In 5 cases (25%), the incorrect LDLT by ultrasound was selected ; and one (5%) was found to have an unsatisfactory lung collapse. Conclusion: Measurement of the outer tracheal width by ultrasound can be a useful method for predicting the diameter of left main bronchus and for selecting a LDLT.

Thoracic anesthesia; Double-lumen endobronchial tube; Ultrasonography

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

20 (4)

2008.

247-252

objavljeno

0952-8180

Povezanost rada

Kliničke medicinske znanosti

Indeksiranost