Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Disinfection byproduct formation according to type of disinfectant used (CROSBI ID 147345)

Prilog u časopisu | izvorni znanstveni rad

Tofant, Alenka ; Brižić, Ljiljana ; Perković, Zdravko ; Venglovský, Jan Disinfection byproduct formation according to type of disinfectant used // Folia veterinaria, 52 (2008), 2; 93-94

Podaci o odgovornosti

Tofant, Alenka ; Brižić, Ljiljana ; Perković, Zdravko ; Venglovský, Jan

engleski

Disinfection byproduct formation according to type of disinfectant used

Results of the Petrinja-Sisak water supply system safety testing for potentially harmful disinfection by-products collected over years are presented. They showed that the formation of trihalomethanes (THMs) was significant only when gaseous chlorine was used in pretreatment and as the final disinfectant. Chlorine dioxide produced little THMs, and chlorite concentration detected was below guideline values. Preozonation generally decreased THMs formation from postchlorination, either chlorine or chlorine dioxide was used as secondary disinfectant.

drinking water; ozone; chlorine; chlorine dioxide; disinfection byproducts

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

52 (2)

2008.

93-94

objavljeno

0015-5748

Povezanost rada

Javno zdravstvo i zdravstvena zaštita