Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Detection of HEMA in self-etching adhesive systems using high performance liquid chromatography (CROSBI ID 542263)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Pandurić, Vlatko ; Tarle, Zrinka ; Hameršak, Zdenko ; Stipetić, Irena ; Matošević, Danijela ; Negovetić Mandić, Višnja ; Prskalo, Katica Detection of HEMA in self-etching adhesive systems using high performance liquid chromatography // EUCMOS 2008, XXIX European Congress on Molecular Spectroscopy Book of Abstracts / Musić, Svetozar ; Ristić, Mira ; Krehula, Stjepko (ur.). Zagreb: Institut Ruđer Bošković, 2008. str. 246-246

Podaci o odgovornosti

Pandurić, Vlatko ; Tarle, Zrinka ; Hameršak, Zdenko ; Stipetić, Irena ; Matošević, Danijela ; Negovetić Mandić, Višnja ; Prskalo, Katica

engleski

Detection of HEMA in self-etching adhesive systems using high performance liquid chromatography

One of the factors that can decrease hydrolytic stability of self-etching adhesive systems (SEAS) is 2- hydroxymethylmethacrylate (HEMA). Due to hydrolytic instability of acidic methacrylate monomers in SEAS, HEMA can be present even if the manufacturer did not include it in original composition. The aim of the study was to determine the presence of HEMA because of decomposition by hydrolysis of methacrylates during storage, resulting with loss of adhesion strength to hard dental tissues of the tooth crown. Three most commonly used SEAS were tested: AdheSE ONE, G-Bond and iBond under different storage conditions. High performance liquid chromatography analysis was performed on a Nucleosil C18-100 5  m (250x4.6 mm) column, Knauer K-501 pumps and Wellchrom DAD K-2700 detector at 215 nm. Data were collected and processed by EuroCrom 2000 HPLC software. Calibration curves were made related eluted peak area to known concentrations of HEMA (purchased from Fluka). The elution time for HEMA is 12.25 min at flow rate 1.0 ml/min. Obtained results indicate that no HEMA was present in AdheSE ONE because methacrylates are substituted with methacrylamides that seem to be more stable under acidic aqueous conditions. In all other adhesive systems HEMA was detected.

high performance liquid chromatography; self-etching adhesive systems; HEMA

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

246-246.

2008.

objavljeno

Podaci o matičnoj publikaciji

EUCMOS 2008, XXIX European Congress on Molecular Spectroscopy Book of Abstracts

Musić, Svetozar ; Ristić, Mira ; Krehula, Stjepko

Zagreb: Institut Ruđer Bošković

978-953-6690-76-3

Podaci o skupu

XXIX European Congress on MOlecular Spectroscopy

poster

31.08.2008-05.09.2008

Opatija, Hrvatska

Povezanost rada

Kemija, Dentalna medicina