Napredna pretraga

Pregled bibliografske jedinice broj: 364051

CALIBRATION OF 3D KINEMATIC SYSTEMS USING 2D CALIBRATION PLATE


Pribanić, Tomislav; Joaquim, Salvi; Kasović, Mario
CALIBRATION OF 3D KINEMATIC SYSTEMS USING 2D CALIBRATION PLATE // Proceedings of XXVI International Conference on Biomechanics in Sports / Kwon, Young-Hoo ; Shim, Jaeho ; Shim Jae K. ; Shin, In-Sik (ur.).
Seoul, Korea: Rainbowbooks, Korea, 2008. str. 77-80 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


Naslov
CALIBRATION OF 3D KINEMATIC SYSTEMS USING 2D CALIBRATION PLATE

Autori
Pribanić, Tomislav ; Joaquim, Salvi ; Kasović, Mario

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of XXVI International Conference on Biomechanics in Sports / Kwon, Young-Hoo ; Shim, Jaeho ; Shim Jae K. ; Shin, In-Sik - Seoul, Korea : Rainbowbooks, Korea, 2008, 77-80

ISBN
978-89-6206-022-5

Skup
The XXVI International Conference on Biomechanics in Sports

Mjesto i datum
Seoul, Korea, 14-18.07.2008

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
3D kinematic system; camera calibration; 2D calibration plate; wand calibration

Sažetak
3D kinematic systems based on the images acquired by cameras are one of the most popular tools for a human motion analyses. Prior to the actual reconstruction a camera calibration procedure is needed. Originally 3D calibration cages were utilized for that purpose, but nowadays a vast majority of commercial systems rely on the wand calibration. When the highest degree of accuracy is requested, than using 3D calibration cage is often recommended over the wand calibration. On the other hand, from a user point of view a wand calibration is generally regarded as the most user friendly. A substantial ‘ intermediate’ solution would be using 2D calibration plate. Interestingly, there could be hardly found any trace that commercial 3D kinematic systems ever relied on 2D calibration plate. The purpose of this study was to investigate quantitative and qualitative aspects of calibrating the 3D kinematic system using 2D calibration plate.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika, Računarstvo, Pedagogija



POVEZANOST RADA


Projekt / tema
034-0362979-2334 - Automatizirano mjerenje pokreta i ekspertna procjena u studiju lokomocije (Vladimir Medved, )
036-0362979-1554 - Neinvazivna mjerenja i postupci u biomedicini (Stanko Tonković, )

Ustanove
Kineziološki fakultet, Zagreb,
Fakultet elektrotehnike i računarstva, Zagreb