Analysis of Small Break LOCA During Mode 3 and Mode 4 Operation for NPP Krško (CROSBI ID 538916)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Šadek, Siniša ; Špalj, Srđan ; Bajs, Tomislav Analysis of Small Break LOCA During Mode 3 and Mode 4 Operation for NPP Krško // Proceedings of the International Conference Nuclear Energy for New Europe 2007 / Jenčič, Igor ; Lenošek, Melita (ur.). Ljubljana: Nuclear Society of Slovenia, 2007. str. 215.1-215.8

Podaci o odgovornosti

Šadek, Siniša ; Špalj, Srđan ; Bajs, Tomislav

engleski

Analysis of Small Break LOCA During Mode 3 and Mode 4 Operation for NPP Krško

Small break loss of coolant accident (SB LOCA) analysis using RELAP5/Mod3.3 computer code during NPP Krško operation in shutdown modes (Mode 3 and Mode 4) was done in order to test the performance of the emergency core cooling system (ECCS) to mitigate such an event. ECCS is normally tested against a large break LOCA occurring at full power conditions because much higher core heat generation rates exist during full power operation. Nevertheless, ECCS system should provide protection in all modes of operation. Probability of a large break LOCA occurrence during Mode 3 and Mode 4 operation is very low, therefore only the analysis of the small break LOCA (break equivalent to that of six inch diameter) in the cold leg was performed. During Mode 3 or Mode 4 operation, the normal alignment of ECCS equipment is different than during the power operation. Accumulators are isolated and the automatic safety injection signal on low pressurizer pressure is blocked. Therefore, in these modes of operation, the operator action is required to mitigate the consequences of a LOCA event. The objective of the analyses was to demonstrate that the consequences of LOCA would be mitigated and the limits of 10CFR50.46 would not be exceeded if there was a timely operator action to initiate safety injection flow.

Small break LOCA; NPP; RELAP5

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

215.1-215.8.

2007.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of the International Conference Nuclear Energy for New Europe 2007

Jenčič, Igor ; Lenošek, Melita

Ljubljana: Nuclear Society of Slovenia

978-961-6207-28-7

Podaci o skupu

International Conference Nuclear Energy for New Europe 2007

poster

10.09.2007-13.09.2007

Portorož, Slovenija

Povezanost rada

Elektrotehnika