Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Population study at fifteen short tandem repeat loci in the representative sample of Bosnia and Herzegovina residents - contemporary data (CROSBI ID 537385)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Marjanović, Damir ; Durmic-Pasic, Adaleta ; Pjanic, N ; Bakal, Narcisa ; Kovačević, Lejla ; Škaro, Vedrana ; Projić, Petar ; Haverić, Sanin ; Bajrović, Kasim ; Hadžiselimović, Rifat et al. Population study at fifteen short tandem repeat loci in the representative sample of Bosnia and Herzegovina residents - contemporary data // European journal of human genetics. 2007. str. 305-305

Podaci o odgovornosti

Marjanović, Damir ; Durmic-Pasic, Adaleta ; Pjanic, N ; Bakal, Narcisa ; Kovačević, Lejla ; Škaro, Vedrana ; Projić, Petar ; Haverić, Sanin ; Bajrović, Kasim ; Hadžiselimović, Rifat ; Primorac, Dragan ; Pojskić Naris

engleski

Population study at fifteen short tandem repeat loci in the representative sample of Bosnia and Herzegovina residents - contemporary data

In our previous population studies of B&H human population, we used 17 autosomal and 12 Y-chromosomal STR loci, as well as 28 NRY bi-allelic markers to generate referent database. Wishing to test our database in order to obtain specific results in various DNA analysis, we have decided to analysis additional individuals, firstly at fifteen autosomal STR loci (D3S1358, TH01, D21S11, D18S51, Penta E, D5S818, D13S317, D7S820, D16S539, CSF1PO, Penta D, vWA, D8S1179, TPOX, FGA). Therefore, we have tested additional group of 100 unrelated healthy individuals born in B&H. Qiagen DnaeasyTM Tissue Kit was used for DNA extraction from buccal swabs and bloodstains and PowerPlex 16® ; ; System for amplification and detection. The total volume of PCR reaction was 5μ l and PCR amplifications were carried out in PE GeneAmp PCR System Thermal Cycler. Electrophoresis of the amplification products was preformed on an ABI PRISM 310 genetic analyzer. The raw data were compiled and analyzed using Genemapper® ; ; v3.2. Deviation from Hardy-Weinberg equilibrium, observed and expected heterozygosity, power of discrimination and power of exclusion were calculated. Statistical differences between the new set of data and the data at same loci published earlier (based on 100 tested individuals) indicated the advantage of using recently obtained frequencies, especially as it pertains to the forensic-genetic statistical analysis. In addition, we compared B&H data with the data obtained from geographically closer European populations. The results of this study will be used as guidelines in additional improving of investigation of recent B&H human populations, initiated in our previous studies.

STR loci; renewed data; Bosnia & Herzegovina

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

305-305.

2007.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

European journal of human genetics

Nature publishing group

1018-4813

Podaci o skupu

European Human Genetics Conference

poster

16.06.2007-19.06.2007

Nica, Francuska

Povezanost rada

Biologija

Indeksiranost