Effects of background substraction on differential kidney function measured by static scintigraphy with DMSA and dynamic scintigraphy with MAG 3 (CROSBI ID 140297)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Girotto, Neva ; Smokvina, Aleksandar ; Ivanković Grbac, Svjetlana ; Licul, Vanja Effects of background substraction on differential kidney function measured by static scintigraphy with DMSA and dynamic scintigraphy with MAG 3 // Nuklearmedizin, 47 (2008), 1; 43-47

Podaci o odgovornosti

Girotto, Neva ; Smokvina, Aleksandar ; Ivanković Grbac, Svjetlana ; Licul, Vanja

engleski

Effects of background substraction on differential kidney function measured by static scintigraphy with DMSA and dynamic scintigraphy with MAG 3

The aim of this study was to assess the influence of background subtraction (BS) on estimation of differential kidney function (DF) on the static scintigraphy with Tc-99m dimercaptosuccinic acid (DMSA) and dynamic scintigraphy with Tc-99m mercaptoacetyltriglicine (MAG3) and to establish possible differences between DF values estimated with these methods. Patients, methods: Patients (n = 106) were selected among those scheduled to static and dynamic scintigraphies within 3 months, with no interim clinical and laboratory changes, regardless the kidney pathology. DF was estimated according to the uptake ratio method. Four background regions of interest (ROls) were applied, identical for both studies, and DF values were recalculated after BS. The corrected values were compared to the values before correction, separately for DMSA and MAG3, and between the studies. The results showed that ROls used introduce variable results for the some patients, predominantly when noncorrected DF values were < 45%. There were no significant differences between DF values (corrected and noncorrected) obtained from static and dynamic scintigraphy in all groups of patients. Since numerous reasons can bring to the errors in DF estimation when BS is used, the conclusions ore that it would probably be more accurate to avoid BS, particularly when DF values are compared in a patient follow-up, and when kidney function is normal. BS should he used, but always in the same way, only when there is a significant difference in kidney size, or when DF is < 25%, since background activity is then considerable. MAG3 and DMSA can be equally used for DF estimation and their results compared in patient follow-up.

kidney; Tc-99m-DMSA; Tc-99m-MAG3; scintigraphy; differential function; background subtraction