Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Design of 40 MVA two-pole two-speed generator for special purposes in testing laboratory (CROSBI ID 536344)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Čelić, Kristina ; Pužar, Milica ; Berberović, Sead Design of 40 MVA two-pole two-speed generator for special purposes in testing laboratory // The Eleventh International Middle-East Power Systems Conference - MEPCON 2006. Minya: University of El-Minia, 2006. str. 1-11

Podaci o odgovornosti

Čelić, Kristina ; Pužar, Milica ; Berberović, Sead

engleski

Design of 40 MVA two-pole two-speed generator for special purposes in testing laboratory

This paper deals with basic performances of a design of a two-pole three-phase 40MVA synchronous generator designed for special operating conditions in laboratory for testing high power transformers. The generator is designed to test three-phase and single-phase transformers aimed to work within 50 Hz and 60 Hz network frequency. This means that the generator will operate at two nominal speeds, at 3000 rpm and 3600 rpm, with nominal power of 40 MVAr induction load when rating with symmetrical three-phase load. The additional requirements relate to constant operation with two-phase 25 MVA load and single-phase 13.5 MVA load, since for testing single-phase and special transformers phase connection you like will be used. In the course of designing, special attention was paid to correct dimensioning of the damper rotor winding as well as to the geometry of stator windings, rotor and air gap, which in the end will produce minimum voltage wave distortion, i.e. generator voltage wave shape with harmonious content less than 1% (as it was demanded).

AC generator; equivalent circuits; finite-element analysis; inverse system; operating performance; losses; stator damper winding; synchronous generator

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

1-11.

2006.

objavljeno

Podaci o matičnoj publikaciji

The Eleventh International Middle-East Power Systems Conference - MEPCON 2006

Minya: University of El-Minia

Podaci o skupu

The Eleventh International Middle-East Power Systems Conference - MEPCON 2006

predavanje

19.12.2006-21.12.2006

Minya, Egipat

Povezanost rada

Elektrotehnika