Application of control volume numerical method in thermographic analysis of relative material loss (CROSBI ID 534197)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Švaić, Srećko ; Boras, Ivanka
engleski
Application of control volume numerical method in thermographic analysis of relative material loss
Application of IR thermography for revealing and estimation of corrosion intensity seems to have a good perspective as a non destructive method. Beside the limitations which are the results of IR camera itself and thermal properties of the material detected, when combined with adequate numerical method the acceptable results can be obtained. The paper presents the comparison of the results obtained by simulation by means of software developed by authors and the results obtained by thermographic measurement presented by Marinetti, Bison and Grinzato in reference [1].
control volume numerical method; material loss; hidden defects
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
2006.
objavljeno
Podaci o matičnoj publikaciji
Proceedings of QIRT 2006
Daniel L. Balageas
Padova: QIRT Steering Committee
Podaci o skupu
QIRT 2008
poster
28.06.2006-30.06.2006
Padova, Italija