Radiation Protection Control Area around Passenger Baggage X-Ray Units (CROSBI ID 531602)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa

Prlić, Ivica ; Surić Mihić, Marija ; Meštrović, Tomislav ; Cerovac, Zdravko Radiation Protection Control Area around Passenger Baggage X-Ray Units // Regional and Global Aspects of Radiation Protection IRPA Regional Congress for Central and Eastern Europe Final Programme and Abstracts. Brasov: IRPA, RSRP, 2007. str. T7 O-2: 144-x

Podaci o odgovornosti

Prlić, Ivica ; Surić Mihić, Marija ; Meštrović, Tomislav ; Cerovac, Zdravko

engleski

Radiation Protection Control Area around Passenger Baggage X-Ray Units

Checking passengers and their hand baggagefor explosives and illegal or dangerous items and protecting transit system from acts ot terror presents unique security challenges. The number of new x-ray inspection systems installed on the airports raised the question about the radiation protection of security workwrs and passengers. Radiation exposure from baggage control x-ray units is to be recognized as a private/or group hazard of each person alone. We have utilized an active electronic dosemeter (AED) to be uesd for real time measurements of security workers "possible" occupational dose. We measured the area dose around the baggage control x-ray unit in order to establish the control areas of concern if any. Measurement were performed for a period of more than one year taking into account the passenger number, the number of items scanned and the x-ray radiation quality. The result is that the working area near the x-ray baggage control unit used for hand baggage security scanning on airports is not to be regarded as radiation protection control area nor area of concern if the workers are obeying teh security procedure rules. If properly installed, used and maintained x-ray control units used for security purposes is not repersent any radiation exposure risk to the passengers.

radiation protection; radiation exposure risk; active electronic dosemeter; x.ray unit; control area

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

T7 O-2: 144-x.

2007.

objavljeno

Podaci o matičnoj publikaciji

Podaci o skupu

IRPA Regional Congress for Central and Eastern Europe "Regional and Global Aspects of Radiation Protection"

predavanje

24.09.2007-28.09.2007

Brašov, Rumunjska

Povezanost rada

Fizika, Javno zdravstvo i zdravstvena zaštita