Characterisation of radiophotoluminescent dosimeters for environmental monitoring (CROSBI ID 134419)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Ranogajec-Komor, Maria ; Knežević, Željka ; Miljanić, Saveta ; Vekić, Branko Characterisation of radiophotoluminescent dosimeters for environmental monitoring // Radiation measurements, 43 (2008), 2-6; 392-396. doi: 10.1016/j.radmeas.2007.11.020

Podaci o odgovornosti

Ranogajec-Komor, Maria ; Knežević, Željka ; Miljanić, Saveta ; Vekić, Branko

engleski

Characterisation of radiophotoluminescent dosimeters for environmental monitoring

Solid state dosimetry systems, including the early radiophotoluminescent (RPL) glass dosimeters, were investigated for application in environmental monitoring. RPL systems are under permanent development. The following dosimetric characteristics of the recently developed SC-1 flat RPL glass dosimeters with FGD-202 reader for environmental dosimetry were investigated: uniformity/batch homogeneity, reproducibility, linearity, detection threshold, energy dependence in air, on phantom and in water as well as the light sensitivity. All characteristics investigated fulfil the requirements of the IEC 61066:2006 Standard for personal and environmental dosimetry (IEC, 2006). It was found, that while the dosimeter is not sensitive for light because of automatic manipulation, the glass element itself could be used for 254 nm UV irradiation measurement. The UV light sensitivity differs for unirradiated and irradiated glass element. The authors recommend to extend the IEC Standard for personal and environmental monitoring also for RPL (and other) passive solid state dosimeters.

RPL ; glass dosimeters ; environmental monitoring ; light sensitivity ; energy dependence ; IEC standards

Proceedings 15th Solid State Dosimetry Conference (SSD15)

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

43 (2-6)

2008.

392-396

objavljeno

1350-4487

10.1016/j.radmeas.2007.11.020

Povezanost rada

Fizika, Kemija

Poveznice
Indeksiranost