Diagnostic accuracy of C-reactive protein, total leukocyte count, platelet count and diffrential blood count in newborn sepsis (CROSBI ID 530837)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Margetić, Sandra ; Topić, Elizabeta ; Gjerek, Jadranka Diagnostic accuracy of C-reactive protein, total leukocyte count, platelet count and diffrential blood count in newborn sepsis // Clinical chemistry and laboratory medicine / Siest, Gerard (ur.). 2007. str. M198-x

Podaci o odgovornosti

Margetić, Sandra ; Topić, Elizabeta ; Gjerek, Jadranka

engleski

Diagnostic accuracy of C-reactive protein, total leukocyte count, platelet count and diffrential blood count in newborn sepsis

Determination of C-reactive protein (CRP), total leukocyte count, platelet count (PLT) and differential blood count (DBC) repre sents a „ sepsa-sc reen“ diagnostic approach in newborns clini cally suspected of sepsis. The aim of the study was to assess diagnostic acc uracy of these pa rameters in newborns with sepsis. Materials and methods. The study inclu ded 58 newborns with sepsis and 328 healthy newborns. CRP concentration was determined by particle enhanced immunoturbidimetric assay (Olympus AU2700). Complete blood count was determined on an automated blood counter (Cell-Dyn 3200, Abbott Diagnostics). DBC was determined by microscopic method in stained periphera l blood smear. Di agnostic accuracy was evaluated using the receiver opera ting characteristic (ROC) analysis. Results. ROC analysis showed excellent discriminating powe rof CRP (AUC=0.970, sensitivity (Se)=89.7%, specificity (Sp)=96%, cut-off >11.5 mg/L. Among the parameters of DBC, acceptable diagnostic accuracy was obtained for immature to total neutrophil ratio (I/T ratio, AUC=0.789, Se=77 .2%, Sp=73.2%, cut-ff>0.11), immature t o mature neutrophil ratio (I/M ratio, AUC=0.774, Se=75%, Sp=73.6%, cut-off>0.13) and percentage of band cells (AUC=0.784, Se=82.8%, Sp=66.2%, cut-off>5%). Absolute neutrophil count (AUC=0.607, Se=54.7%, Sp=66.1%), lymphocyte count (AUC=0.659, Se=82.5%, Sp=47.9%), total leukocyte count (AUC=0.629, Se=65.5%, Sp=56.9%) and platlet count (AUC=0.542, Se=62.1%, Sp=49.2%) showed unacceptable discriminating power in the diagnosis of neonata l sepsis. Conclusions. The concentration of CRP showed the best diagnostic accuracy in the diagnosis of neonatal sepsis. Acceptable discriminating power i n the diagnosis of neonatal sepsis showed I/T and I/M ratios and percentage of band cells. Total leukocyte count and platele t count are not reliable diagnostic indicators of neonatal sepsis.

C-reactive protein; Leukocyte count; Platelet count; Newborn; Sepsis

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

M198-x.

2007.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Clinical chemistry and laboratory medicine

Siest, Gerard

Berlin: Walter de Gruyter

1434-6621

Podaci o skupu

17th European Congress of Clinical Chemistry and Laboratory Medicine, Euromedlab 2007

poster

04.06.2007-07.06.2007

Amsterdam, Nizozemska

Povezanost rada

Kliničke medicinske znanosti

Indeksiranost