Voltammetry as an Alternative Tool for Trace Metal Detection in Peloid Marine Sediments (CROSBI ID 133543)
Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Ciglenečki, Irena ; Bura-Nakić, Elvira ; Inzelt, György
engleski
Voltammetry as an Alternative Tool for Trace Metal Detection in Peloid Marine Sediments
Here was demonstrated for the first time a possible application of abrasive stripping voltammetry in the direct measurement of trace metals in anoxic, sulfidic marine sediments (peloid mud) from a small and shallow (0.2-1 m) marine lagoon in Central Dalmatia, Croatia. Trace amounts of sample compounds are transferred to the graphite electrode surface and electrochemical reduction or oxidation processes are followed by the cyclic voltammetry in seawater or 0.55 M NaCl as electrolyte. After a preelectrolysis at potentials ranging from -1.0 to -1.5 V (vs. SCE) a well-defined anodic stripping peak corresponding to the oxidation of metal deposits generated at deposition potentials is obtained around -0.74 V (vs. SCE). The same samples were studied by anodic stripping voltammetry at the Hg electrode and inductively coupled plasma-mass spectrometer (ICP-MS). ICP-MS showed higher concentrations of trace metals such as Al, Fe, Mo, Mn. A relatively high concentration of reduced sulfur species (RSS) (10-3 M) is determined electrochemically in porewater of the peloid mud, indicating that the magnitude of metal enrichment in the sediments is probably controlled by precipitation with sulfide.
abrasive stripping voltammetry; trace metals; sulfides; peloid muds; anoxic conditions