Improvement of the cogeneration plant economy by using heat accumulator (CROSBI ID 126894)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Bogdan, Željko ; Kopjar, Damir Improvement of the cogeneration plant economy by using heat accumulator // Energy (Oxford), 31 (2006), 13; 1949-1956-x

Podaci o odgovornosti

Bogdan, Željko ; Kopjar, Damir

engleski

Improvement of the cogeneration plant economy by using heat accumulator

The optimisation code ACOM (Advanced Cogeneration Optimization Model) is used with purpose of assessing influence of the district heat accumulator on the EL-TO (Elektrana-Toplana) Zagreb cogeneration plant economic performance. The plant supplies hot water for district heating, steam for industry and electric power. It is possible to achieve economic benefits by charging the accumulator during the day time, when the electricity price is high, and by releasing district heat during cheap night hours when other parts of equipment may be shut down. The consequences of this strategy are the decrease of total annual electricity production and fuel consumption, whereby the savings of some 1.8 mil Euro/a are achieved with the reduction of CO2 emission for about 23, 000 t/a or 6.4 % and SOx for about 200 t/a or 16.9 %.

cogeneration; heat accumulator

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

31 (13)

2006.

1949-1956-x

objavljeno

0360-5442

Povezanost rada

Strojarstvo

Indeksiranost