Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

The efficacy of gradient percoll on bull sperm separation for in vitro fertilization (CROSBI ID 126510)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Samardžija, Marko ; Dobranić, Tomislav ; Karadjole, Martina ; Getz, Iva ; Vince, Silvijo ; Gračner, Damjan ; Maćešić, Nino ; Filaković, Ivana The efficacy of gradient percoll on bull sperm separation for in vitro fertilization // Veterinarski arhiv, 76 (2006), 1; 37-44

Podaci o odgovornosti

Samardžija, Marko ; Dobranić, Tomislav ; Karadjole, Martina ; Getz, Iva ; Vince, Silvijo ; Gračner, Damjan ; Maćešić, Nino ; Filaković, Ivana

engleski

The efficacy of gradient percoll on bull sperm separation for in vitro fertilization

In the present study we examined the effect of density gradient preparation Percoll® ; on bull sperm separation and in vitro fertilization (IVF) results. Frozen/thawed semen from 5 Simmental bulls was pooled and sperm quality parameters were evaluated before and after sperm separation using Percoll® ; density gradient preparation. We evaluated sperm motility (subjective), sperm concentration (Thoma chamber) and sperm membrane activity by HOS assay. Initial sperm parameters results were as follows: motility 50%, sperm concentration 80.80 x 106 spz/mL and functional integrity of sperm cells 39.25%. Final sperm motility was 63%, final sperm concentration 28 x 106 spz/mL and HOS assay results after Percoll® ; gradient was 57.60%. A total of 211 oocytes were matured and fertilized in vitro and cultured in SOFaaBSA in five repetitions. The cleavage (D2), blastocysts (D7) and hatched blastocysts (D10) were 63.13%, 20.38%, and 10.64%, respectively. We found no significant correlations between sperm parameters and IVF results (r<0.5 ; P>0.05). It is possible to conclude that sperm evaluation parameters after sperm separation by gradient Percoll® ; are not reliable in predicting the outcome of IVF. However, using gradient Percoll® ; for sperm separation in IVF is necessary to improve the quality of separated sperm able to significantly improve sperm quality with a high rate of progressive motility and morphological normal spermatozoa.

bull; sperm; fertilization; Percoll® ;

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

76 (1)

2006.

37-44

objavljeno

0372-5480

Povezanost rada

Veterinarska medicina

Poveznice
Indeksiranost