Is sonographic assessment of cervical length better than digital examination in screening for preterm delivery in a low-risk population? (CROSBI ID 120937)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Matijević, Ratko ; Grgić, Ozren ; Vasilj, Oliver Is sonographic assessment of cervical length better than digital examination in screening for preterm delivery in a low-risk population? // Acta obstetricia et gynecologica Scandinavica, 85 (2006), 11; 1342-1347-x

Podaci o odgovornosti

Matijević, Ratko ; Grgić, Ozren ; Vasilj, Oliver

engleski

Is sonographic assessment of cervical length better than digital examination in screening for preterm delivery in a low-risk population?

Background: This randomized controlled trial compared the diagnostic accuracy of the sonographic assessment of cervical length and clinical digital examination of the cervix in the second trimester regarding the prediction of preterm delivery in low-risk population. Methods: Totally, 282 unselected, asymptomatic, women with singleton pregnancy randomly underwent sonographic cervical length measurement (study group, n=138) or clinical digital examination (control group, n=144) in the second trimester. In the study group cervical length < 5th percentile (< 24mm) for our population was defined as shortened. In the control group, Bishop score > 95th percentile (> 4) for our population was defined as high. Primary outcome measure included the diagnostic accuracy of both tests regarding the prediction of preterm delivery (< 37 weeks). Results: Shortened cervical length was found in 6/138 (4.3%) whereas the high Bishop score was found in 17/144 (11.8%) (p = 0.038, Fisher exact test). The incidence of preterm delivery was 5.7 % (16/282). Regarding the prediction of preterm delivery, shortened cervical length and high Bishop score had sensitivity 57.1 % vs. 33.3 % and positive predictive value 66.7 % vs. 17.6 %. Shortened cervical length in comparison with high Bishop score had 12-fold higher positive likelihood ratio for preterm delivery in low-risk population (37.4 ; 95%CI [8.2-170.7] vs. 3.2 ; 95%CI [1.1-9.2]). Conclusion: Sonographic assessment of cervical length has better diagnostic accuracy in the prediction of preterm delivery compared to digital examination in low-risk population.

low-risk population; transvaginal cervical sonography; digital examination; Bishop score; second trimester; preterm delivery

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

85 (11)

2006.

1342-1347-x

objavljeno

0001-6349

Povezanost rada

Kliničke medicinske znanosti

Indeksiranost