Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Levosimendan as a New Strategy During Off-pump Coronary Artery Bypass Grafting: Double-blind Randomized Placebo-controlled Trial (CROSBI ID 119060)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Husedžinović, Ino ; Barišin, Stjepan ; Bradić, Nikola ; Barišin, Ana ; Sonički, Zdenko ; Milanović, Rudolf Levosimendan as a New Strategy During Off-pump Coronary Artery Bypass Grafting: Double-blind Randomized Placebo-controlled Trial // Croatian medical journal, 46 (2005), 6; 950-956

Podaci o odgovornosti

Husedžinović, Ino ; Barišin, Stjepan ; Bradić, Nikola ; Barišin, Ana ; Sonički, Zdenko ; Milanović, Rudolf

engleski

Levosimendan as a New Strategy During Off-pump Coronary Artery Bypass Grafting: Double-blind Randomized Placebo-controlled Trial

Aim was to determine if levosimendan could improve cardiac performance during off-pump coronary artery bypass grafting in patients with normal preoperative left ventricular function. Twenty-four patients included in this double-blind randomized controlled trial received either placebo (n=12) or 12  g/kg loading dose of levosimendan (n=12) during a period of 15 minutes before the surgery. The heart rate, cardiac index, stroke volume index, and left ventricular ejection fraction were measured before and 10 and 60 minutes after the drug administration. The baseline measurements of hemodynamic parameters did not differ between the groups. Heart rate was not significantly different between the placebo and levosimendan group. Compared with placebo group, cardiac index and left ventricular ejection fraction were significantly higher 10 and 60 minutes (p=0.018 for all) after administration of levosimendan. After 60 minutes, the cardiac index increased from the baseline value of 2.18 L/min/m2 to 2.84 L/min/m2. Left ventricular ejection fraction increased by 14% after 10 minutes, and by 10% after 60 minutes. Stroke volume index was significantly higher at 10 minutes (p=0.018), but not at 60 minutes (p=0.063) after the administration of levosimendan. Administration of 12  g/kg of levosimendan enhances the left ventricular performance and offers a promising therapeutic option during off-pump coronary artery bypass grafting in patients with good preoperative left ventricular function.

Levosimendan; Off-pump cardiac surgery; hemodynamic

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

46 (6)

2005.

950-956

objavljeno