Time To First EEG Seizure During Continuous Video/EEG Telemetry (CROSBI ID 117004)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Hećimović, Hrvoje ; Gillam, Frank Time To First EEG Seizure During Continuous Video/EEG Telemetry // Acta clinica Croatica, 44 (2005), 2; 105-107-x

Podaci o odgovornosti

Hećimović, Hrvoje ; Gillam, Frank

engleski

Time To First EEG Seizure During Continuous Video/EEG Telemetry

Correlation between time to first scalp EEG seizure during video/EEG telemetry and self-reported seizure frequency was determined in refractory epilepsy patients... 82 consqutive epilepsy patients were preoperatively evaluated... Self reported seizure frequency did not predict the time to first scalp EEG seizure in the seizure monitoring unit. Self-reported seizure frequency was a poor predictor of time to first scalp EEG seizure. This finding suggests that patients with less frequent self-reported sezure rates should also be considered as good candidates for further evaluation, including scalp and intracranial/EEG telemetry.

Electroencephalography-methods; Seizures-diagnosis; Continuous video/EEG monitoring

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

44 (2)

2005.

105-107-x

objavljeno

0353-9466

Povezanost rada

Kliničke medicinske znanosti

Indeksiranost