Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Human blood molybdenum: Comparison of differential pulsed anodic stripping voltametry (DPASV), thermal emission atomic absorption spectrometry (ET-AAS), and inductively coupled plasma mass spectrometry (ICP-MS). (CROSBI ID 510144)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Momcilovic, Berislav ; Ivicic, Nikola ; Jurasovic, Jasna ; Kopjar, Nevenka ; Morovic, Jadran ; Skalny, Anatoly, V ; Grebeklis, Andrei, R ; Serebryansky, Evgenij, P. Human blood molybdenum: Comparison of differential pulsed anodic stripping voltametry (DPASV), thermal emission atomic absorption spectrometry (ET-AAS), and inductively coupled plasma mass spectrometry (ICP-MS). // TEMA 12. 12th International Symposium on Trace Elements in Man and Animals. Book of Abstracts. / Strain J. James (Sean) (ur.). Coleraine: University of Ulster, 2005. str. 64-x

Podaci o odgovornosti

Momcilovic, Berislav ; Ivicic, Nikola ; Jurasovic, Jasna ; Kopjar, Nevenka ; Morovic, Jadran ; Skalny, Anatoly, V ; Grebeklis, Andrei, R ; Serebryansky, Evgenij, P.

engleski

Human blood molybdenum: Comparison of differential pulsed anodic stripping voltametry (DPASV), thermal emission atomic absorption spectrometry (ET-AAS), and inductively coupled plasma mass spectrometry (ICP-MS).

There were no difference in whole blood molybdenum content as assessed by our newly developed differential pulsed anodic stripping voltametry (DPASV), and electro thermal atomic absorption spectrometry (ET-AAS) and inductively coupled plasma mass spectrometry (ICP-MS) analytical procedures, respectively. Since the analytical data (n=30) showed high skeweness to the right, the median (1.76 micro g Mo L-1) was a better true representative of molybdenum in the blood than the mean (2.55 micro g Mo L-1). The bilogical significance of that skeweness remains to be elucidated.

Molybdenum; human blood; DPASV; ET-AAS; ICP-MS

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

64-x.

2005.

objavljeno

Podaci o matičnoj publikaciji

TEMA 12. 12th International Symposium on Trace Elements in Man and Animals. Book of Abstracts.

Strain J. James (Sean)

Coleraine: University of Ulster

Podaci o skupu

12th International Symposium on Trace Elements in Man and Animals.

poster

19.06.2005-23.06.2005

Coleraine, Ujedinjeno Kraljevstvo

Povezanost rada

Kemija, Temeljne medicinske znanosti, Kliničke medicinske znanosti