Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Evaluation of the Dialab APC sensitivity assay (CROSBI ID 509873)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Coen, Desiree ; Miloš, Marija ; Zadro, Renata Evaluation of the Dialab APC sensitivity assay // Pathophysiology of haemostasis and thrombosis / Rosing, J (ur.). 2003

Podaci o odgovornosti

Coen, Desiree ; Miloš, Marija ; Zadro, Renata

engleski

Evaluation of the Dialab APC sensitivity assay

Introduction: Activated protein C resistance (APCR) has become a well-established part of the thrombophilia screening profile in most laboratories due to a high frequency of Factor V Leiden (FVL) mutation. As several commercial assays of modified APCR (with predilution in FV deficient plasma) are now available, the goal of every coagulation laboratory is to find a sensitive and specific assay that will be suitable for routine work. Aim: The aim of our study was to evaluate the Dialab APC Sensitivity Assay for the laboratory determination of APCR in comparison with DNA analysis. Materials and methods: Plasma samples were obtained from 24 carriers of FVL (19 heterozygotes and 5 homozygotes) and 62 non-carriers, as identified by DNA analysis. Among tested patients 3 heterozygotes and 12 non-carriers were receiving OAT (INR range: 1.61-3.59). APCR was performed on BCT (Dade Behring) coagulation analyzer and the results were expressed as APC ratios. Results: By using a cut-off value of 2.1 we were able to identify all carriers of FVL. No difference in APC ratios was observed between non-carriers receiving OAT or not (p=0.71). There was no overlap of APC ratios between heterozygotes (mean: 1.80, range: 1.62-1.99) and normal controls (mean: 2.85, range: 2.18-3.37) even with elevated F VIII:C levels (181-452 %). There was a clear discrimination between heterozygotes and homozygotes (mean APC ratio: 1.39, range: 1.30-1.48) when a cut-off value of 1.5 was used. Conclusions: Based on our results this test appears to be highly sensitive and specific for the diagnosis of APCR associated with FVL. Furthermore, the test is easy to perform and fulfills the criteria for a screening assay.

evaluation; APC sensitivity assay

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

2003.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Pathophysiology of haemostasis and thrombosis

Rosing, J

Basel: Karger Publishers

1424-8832

Podaci o skupu

Nepoznat skup

poster

29.02.1904-29.02.2096

Povezanost rada

Temeljne medicinske znanosti

Indeksiranost