Performance comparison between wire coil and twisted tape inserts (CROSBI ID 116466)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Malinovec, Marina ; Ponweiser, Karl ; Linzer, Wladimir Performance comparison between wire coil and twisted tape inserts // Journal of enhanced heat transfer, 11 (2004), 4; 359-370-x

Podaci o odgovornosti

Malinovec, Marina ; Ponweiser, Karl ; Linzer, Wladimir

engleski

Performance comparison between wire coil and twisted tape inserts

This work presents experimental results for heat transfer caused by convection of air in tubes with wire coil and twisted tape inserts. The characteristic parameters of the inserted tubes under investigation are length and position in the tube of the tested inserts. All tests are performed in a turbulent flow regime. Significantly higher inside heat transfer and friction factor coefficients than those of the smooth tube under same operating conditions have been observed. The performance of the wire coil and twisted tape inserts has been evaluated by three different criteria: maximizing heat transfer rate, minimizing heat exchanger size, and minimizing pumping power.

wire coil; twisted tape; smooth tube; heat transfer; pressure drop; performance evaluation