Continuous Multiparameter Monitoring of P Wave Parameters after CABG Using Wavelet Detector (CROSBI ID 508470)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Sovilj, Siniša ; Rajsman, Gordana ; Magjarević, Ratko ;
engleski
Continuous Multiparameter Monitoring of P Wave Parameters after CABG Using Wavelet Detector
The aim of the study was to develop methodology for long- term study of ECG parameters, in particular the P wave parameters. In this study we address continuous monitoring of different P wave parameters in the group of patients after Coronary Artery Bypass Grafting (CABG) in order to examine potential predictors of atrial fibrillation. Lead II of the standard surface ECG was recorded in the period of typically 48 hours in patients after CABG. Dyadic wavelet transform analysis with first derivation of Gaussian smoothing function as a mother wavelet, was used for a QRS and a P wave detection, characterization and delineation. During the recording, for every patient, in every hour, vector of 108 P wave components was calculated, allowing continuous and deeper insight into atrial activity.
atrial fibrillation; prediction; p wave; wavelet; coronary artery bypass grafting
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
945-948-x.
2005.
objavljeno
Podaci o matičnoj publikaciji
Computers in Cardiology 2005
Alan, Murray
Lyon: Institute of Electrical and Electronics Engineers (IEEE)
Podaci o skupu
Computers in Cardiology 2005
poster
25.09.2005-28.09.2005
Lyon, Francuska