Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Nonstandard methode in testing of firing pulse of electric detonators (CROSBI ID 508421)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Zorić, Igor ; Kuhinek, Dalibor Nonstandard methode in testing of firing pulse of electric detonators // Proceedings of 19th International Metrology Symposium / Ilić, Damir ; Boršić, Mladen, Jurčević, Marko (ur.). Zagreb: Metrology Consulting, 2005. str. 68-71-x

Podaci o odgovornosti

Zorić, Igor ; Kuhinek, Dalibor

engleski

Nonstandard methode in testing of firing pulse of electric detonators

Electric detonators are tested according to national standards to test their safety and reliability. This is a time consuming process where up to 150 detonators have to be tested. This paper discuses alternative method of testing of firing pulse using programmable current source. Obtained results are possible to compare with standard procedure results.

testing; electric detonator; firing pulse

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

68-71-x.

2005.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of 19th International Metrology Symposium

Ilić, Damir ; Boršić, Mladen, Jurčević, Marko

Zagreb: Metrology Consulting

Podaci o skupu

19th International Metrology Symposium

poster

26.09.2005-28.09.2005

Opatija, Hrvatska

Povezanost rada

Elektrotehnika