National survey of indoor radon levels in Croatia (CROSBI ID 115282)
Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Radolić, Vanja ; Vuković, Branko ; Stanić, Denis ; Katić, Miroslav ; Faj, Zdravko ; Šuveljak, Božica ; Lukačević, Igor ; Faj, Dario ; Lukić, Marko ; Planinić, Josip
engleski
National survey of indoor radon levels in Croatia
National survey of indoor radon was performed by a random sampling of thousand (782 realized) dwellings in Croatia. Radon concentrations were measured for one year with LR-115 SSNT detectors and arithmetic and geometric means of 68 and 50 Bq/m3 were obtained, respectively. The arithmetic means of radon concentrations on 20 counties were from 33 to 198 Bq/m3. The percentage of dwellings with radon concentrations above 200 and 400 Bq/m3 was 5.4 and 1.8%, respectively. The average annual effective dose of the indoor radon was estimated as 2.2 mSv.
indoor radon ; SSNT detector ; log-normal distribution ; annual effective dose