Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Stainless steel crevice corrosion testing in natural and synthetic seawater (CROSBI ID 115048)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Lahodny-Šarc, Olga ; Kulušić, Biserka ; Krstulović, Ljiljana ; Sambrailo, Dubravko ; Ivić, Jure Stainless steel crevice corrosion testing in natural and synthetic seawater // Materials and corrosion, 56 (2005), 8; 561-565-x

Podaci o odgovornosti

Lahodny-Šarc, Olga ; Kulušić, Biserka ; Krstulović, Ljiljana ; Sambrailo, Dubravko ; Ivić, Jure

engleski

Stainless steel crevice corrosion testing in natural and synthetic seawater

Susceptibility of stainless steel to crevice corrosion in natural and synthetic seawater was investigated by a new test method, developed by a research group, CrevCorr, of the Marine Working Party of the European Federation of Corrosion. The method was defined on the basis of the Round Robin test performed by twenty laboratories over the world(1, 2). Among them was our Institute at the Adriatic coast. Geometry of the crevice model, gasket materials, finishing of metal surface and the electrochemical potential increase rate were strictly defined. The monitoring of the free corrosion potential of two austenitic steels and a duplex steel, in the constant flowing conditions, as well as the redox potential, temperature, chloride and oxygn content, have been carried out during six months in the natural seawater from the Adriatic Sea at the location in Dubrovnik, Croatia. Sharp drop of the corrosion potential was used as an indication of the crevice corrosion initiation. After exposure to the seawater eventual crevice damage on a steel specimen was detected by visual and microscopic inspection. In the synthetic seawaer the organic component was simulated by glucose and glucose oxidaze (3, 4). The monitoring of the free corrosion potential and the redox potential was performed at 20, 30 and 40C degrees during five days, and results compared with those obtained in the atural seawater at the same temperature.

stainless steel; crevice corrosion; natural seawater; synthetic seawater

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

56 (8)

2005.

561-565-x

objavljeno

0947-5117

Povezanost rada

Kemijsko inženjerstvo