Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Carotid artery intima thickness and flow velocity after discontimnuation of hormone replacement therapy in postmenopausal women: follow-up study (CROSBI ID 112741)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Pentz-Vidović, Ivana ; Demarin, Vida ; Grubišić, Goran ; Kuna, Krunoslav ; Lovrenčić Huzjan, Arijana Carotid artery intima thickness and flow velocity after discontimnuation of hormone replacement therapy in postmenopausal women: follow-up study // Croatian medical journal, 42 (2001), 1; 54-57-x

Podaci o odgovornosti

Pentz-Vidović, Ivana ; Demarin, Vida ; Grubišić, Goran ; Kuna, Krunoslav ; Lovrenčić Huzjan, Arijana

engleski

Carotid artery intima thickness and flow velocity after discontimnuation of hormone replacement therapy in postmenopausal women: follow-up study

AIM: To investigate the effect of discontinuation of hormone replacement therapy on the intima thickness and blood flow velocity of the common carotid artery. METHODS: The thickness of the left common carotid artery intima and maximal systolic blood velocity were measured by real-time and Doppler ultrasonography in 75 healthy postmenopausal women starting sequential combined hormone replacement therapy. The measurements were performed at the start and after 6 and 12 months of the therapy. Thirty two women decided to discontinue the therapy after 6 months, whereas 43 continued. RESULTS: In the group that continued with the hormone replacement therapy, a significant decrease was recorded in the mean baseline values for carotid artery intima thickness and flow velocity at 6 months (0.35+0.11 vs 0.54+0.19 mm and 0.73+0.16 vs 0.87+0.19 m/s, respectively, p?0.001) and 12 months of follow-up (0.36+0.1 mm and 0.72+0.15 m/s vs baseline, respectively, p?0.001). In women who discontinued the therapy, there were significant deviations from the baseline values in the intima thickness (0.36+0.11 vs. 0.59+0.09 mm, p=0.010) and flow velocity (0.75+0.14 vs. 0.85+0.16 m/s, p?0.001) at 6 but not at 12 months of the follow-up (0.55+0.12 mm, and 0.85+0.17 m/s vs baseline ; p=0.148 and p=0.965, respectively). CONCLUSION: Decreased flow velocity and reduced intima thickness were directly related to blood vessel wall dilatation after estrogen component of hormone replacement therapy. Discontinuation of the hormone replacement therapy returned the flow velocity and intima thickness to their baseline values.

blood flow velocity; carotid artery-common; postmenopause

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

42 (1)

2001.

54-57-x

objavljeno

0353-9504

Povezanost rada

Temeljne medicinske znanosti, Kliničke medicinske znanosti

Indeksiranost