Sigurno pohranjivanje (zbrinjavanje, kondicioniranje) dotrajalih izvora Ra-226 u Hrvatskoj (CROSBI ID 467769)

Prilog sa skupa u zborniku | izvorni znanstveni rad

Vekić, Branko ; Kokot, Ljerka ; Trputec, Veljko ; Bokulić, Tomislav Sigurno pohranjivanje (zbrinjavanje, kondicioniranje) dotrajalih izvora Ra-226 u Hrvatskoj // Zbornik radova Četvrtog simpozija Hrvatskog društva za zaštitu od zračenja / Obelić, Bogomil ; Franić, Zdenko (ur.). Zagreb: Hrvatsko društvo za zaštitu od zračenja, 1998. str. 135-141-x

Podaci o odgovornosti

Vekić, Branko ; Kokot, Ljerka ; Trputec, Veljko ; Bokulić, Tomislav

hrvatski

Sigurno pohranjivanje (zbrinjavanje, kondicioniranje) dotrajalih izvora Ra-226 u Hrvatskoj

For many years radium sources were used for various applications in medicine and industry. Due to their undesirable characteristics, almost all of these sources have been replaced by more modern sources. Storage of these unused sources, especially in developing countries, is often inadequate. Conditioning of radium sources for proper storage is one of major objective of the Waste Technology Section of IAEA. The conditioning of the spent radium sources in Croatia was performed by a specially trained team from the Austrian Research Center Seibersdorf, under contract to the IAEA, using an IAEA developed and approved procedure. The source conditioning took place in a waste storage and treatment facility at the ru|er Bo{;kovi}; Institute, Zagreb, Croatia. The conditioning of the national radium stock in Croatia was performed within the period from 13-17 October 1997. The total inventory was 1316 mg (298 sources, 49 GBq). The sources were mainly needles and tubes. All spent radium sources were conditioned in 25 small capsules and one large capsule. The capsules were put into three shilding devices and two packages (drums) were produced. The total activity/shield is still under the transportation regulation limit. No complications in this operation were experienced. The operation caused no contamination and hence no decontamination was required.

-

nije evidentirano

engleski

Spent radium sources conditioning operation in Croatia

nije evidentirano

-

nije evidentirano

Podaci o prilogu

135-141-x.

1998.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Zbornik radova Četvrtog simpozija Hrvatskog društva za zaštitu od zračenja

Obelić, Bogomil ; Franić, Zdenko

Zagreb: Hrvatsko društvo za zaštitu od zračenja

Podaci o skupu

Četvrti simpozij Hrvatskog društva za zaštitu od zračenja

predavanje

11.11.1998-13.11.1998

Zagreb, Hrvatska

Povezanost rada

Kemija