Površinske doze pacijenata pri CT pretragama abdomena u Općoj bolnici Karlovac (CROSBI ID 467753)

Prilog sa skupa u zborniku | izvorni znanstveni rad

Pavan, Gordana ; Vekić, Branko ; Knežević, Željka ; Ranogajec-Komor, Maria Površinske doze pacijenata pri CT pretragama abdomena u Općoj bolnici Karlovac // Zbornik radova Četvrtog simpozija Hrvatskog društva za zaštitu od zračenja = Proceedings of the 4th Symposium of the Croatian Radiation Protection Association / Obelić, Bogomil ; Franić, Zdenko (ur.). Zagreb: Hrvatsko društvo za zaštitu od zračenja, 1998. str. 315-320-x

Podaci o odgovornosti

Pavan, Gordana ; Vekić, Branko ; Knežević, Željka ; Ranogajec-Komor, Maria

hrvatski

Površinske doze pacijenata pri CT pretragama abdomena u Općoj bolnici Karlovac

Computed tomography (CT) has become a major source of the population exposure to diagnostic X-rays, and acknowledge of the doses delivered by the CT equipment has become very important. Considerable efforts should be made to keep these doses to a reasonable minimum, without sacrificing the image quality. The conditions of exposure in CT are quite different from dose in conventional X-ray imaging. This has required the development of specific techniques for assessing patient dose from CT. The aims of this work were to determine the dose delivered to various organs of patients undergoing computed tomography of abdomen as measured on the surface of the body and to estimate the risk to the patients. Dosimetric measurements were performed at CT scanner Hitachi W 450 in General Hospital Karlovac. The doses absorbed by different organs (gonads, chest, thyroid and eye lens) and by the examined part of the body of 11 patients were measured with TLD-700. The doses absorbed by different organs during the diagnostic CT examination of the body depend on the technical parameters, such as the number of scans, mAs, the thickness of scans, scanning times, tube voltage and other characteristics. The type and severity of illness influence the choice of technical arameters. Clinical parameters, such as patient size and composition, and patient cooperation with regard to the control and motion, also influence the dose and the image quality. The highest dose measured in this study (112.5 mGy) was delivered to front surface of the body during CT examination of abdomen.

nije evidentirano

nije evidentirano

engleski

Patient entrance surface doses during CT examinations of abdomen in General Hospital Karlovac

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

315-320-x.

1998.

objavljeno

Podaci o matičnoj publikaciji

Zbornik radova Četvrtog simpozija Hrvatskog društva za zaštitu od zračenja = Proceedings of the 4th Symposium of the Croatian Radiation Protection Association

Obelić, Bogomil ; Franić, Zdenko

Zagreb: Hrvatsko društvo za zaštitu od zračenja

953-96133-2-9

Podaci o skupu

Četvrti simpozij Hrvatskog društva za zaštitu od zračenja

predavanje

11.11.1998-13.11.1998

Zagreb, Hrvatska