ER:YAG laser vs ultrasound in preparation of root-end cavities (CROSBI ID 503287)
Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija
Podaci o odgovornosti
Karlović, Zoran ; Anić, Ivica ; Miletić, Ivana ; Jukić, Silvana ; Pezelj- Ribarić, Sonja
engleski
ER:YAG laser vs ultrasound in preparation of root-end cavities
The ER:YAG laser had an optimal ablation effect with the lowest temperature rise at 280 mJ and 10 Hz. The time needed for laser root-end cavity preparation was significantly lower than the ultrasound technique. In this in vitro study the ER:YAG laser was more efficient for preparing root-end cavities compared to the ultrasound technique.
root-end cavities; laser; ultrasound
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
39-39.
2003.
nije evidentirano
objavljeno
Podaci o matičnoj publikaciji
0143-2885
Podaci o skupu
Biennial Congress ESE Research (11 ; 2003)
poster
02.10.2003-04.10.2003
Atena, Grčka