Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Measuring sedimentation value in whole wheat grain with near-infrared transmission (CROSBI ID 497064)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Jurković, Zorica ; Sudar, Rezica ; Galonja, Marica ; Šimić, Gordana ; Horvat, Daniela ; Drezner, Georg Measuring sedimentation value in whole wheat grain with near-infrared transmission // Proceedings of International Congress Flour-Brea´03 / Ugarčić-Hardi, Žaneta (ur.). Osijek: Prehrambeno tehnološki fakultet Sveučilišta Josipa Jurja Strossmayera u Osijeku, 2004. str. 109-114

Podaci o odgovornosti

Jurković, Zorica ; Sudar, Rezica ; Galonja, Marica ; Šimić, Gordana ; Horvat, Daniela ; Drezner, Georg

engleski

Measuring sedimentation value in whole wheat grain with near-infrared transmission

Near Infrared Spectroscopy has been used as nondestructive and rapid method for the routine determination of cereal grain constituents (moisture, protein, fat). The quality assessment of cultivars and lines demands an analysis of large number of samples of limited quantity in short time what is difficult to achieve with standard methods therefore, the methods based on near infrared spectroscopy have been widely introduced into breeding programs. In order to determine the sedimentation value, the near infrared transmission (NIT) has been used as a new application since 2002. The aim of this study was to test the application for determination of whole grain sedimentation value on NIT instrument (Infratec 1241 Grain Analyzer). All measured sedimentation values were within calibration limits, and the values for the 215 samples from year 2002 and 647 samples from year 2003 resulted in significant correlation coefficients between NIT and Zeleny method. This research also represents the testing of calibration for sedimentation value provided by the manufacturer based on Croatian cultivars. The raw NIT data will be used for development and improvement of the calibration for measurement of sedimentation value on Infratec 1241. The instrument provides rapid, accurate and reliable data after adjustment of factory-installed calibrations and replaces the more time consuming methods used in breeding programs.

wheat grain; sedimentation value; near infrared transmission

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

109-114.

2004.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of International Congress Flour-Brea´03

Ugarčić-Hardi, Žaneta

Osijek: Prehrambeno tehnološki fakultet Sveučilišta Josipa Jurja Strossmayera u Osijeku

Podaci o skupu

Nepoznat skup

predavanje

29.02.1904-29.02.2096

Povezanost rada

Prehrambena tehnologija