Napredna pretraga

Pregled bibliografske jedinice broj: 150637

Analysis of electro-hydraulic system dead zone influence on the occurrence of the nonlinear resonance jump


Horvat, Krunoslav; Kuljača, Ognjen; Vukić, Zoran
Analysis of electro-hydraulic system dead zone influence on the occurrence of the nonlinear resonance jump // Proceedings of REDISCOVER 2004 : Southeastern Europe, USA, Japan and European Community Workshop on Research and Education in Control and Signal Processing / Bogdan, Stjepan ; Vukić, Zoran (ur.).
Zagreb: Faculty of Electrical Engineering and Computing, University of Zagreb, 2004. (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


Naslov
Analysis of electro-hydraulic system dead zone influence on the occurrence of the nonlinear resonance jump

Autori
Horvat, Krunoslav ; Kuljača, Ognjen ; Vukić, Zoran

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of REDISCOVER 2004 : Southeastern Europe, USA, Japan and European Community Workshop on Research and Education in Control and Signal Processing / Bogdan, Stjepan ; Vukić, Zoran - Zagreb : Faculty of Electrical Engineering and Computing, University of Zagreb, 2004

ISBN
953-184-077-6

Skup
REDISCOVER 2004 : Southeastern Europe, USA, Japan and European Community Workshop on Research and Education in Control and Signal Processing

Mjesto i datum
Cavtat, Hrvatska, 14-16.06.2004

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Nonlinear resonance jump; turbine governor electro-hydraulic servo-positioning system

Sažetak
The paper deals with the analysis of turbine governor positioning system of hydroelectric power plant regarding nonlinear resonance jump caused by dead zone of electro-hydraulic proportional valve. The meanings of the term "resonance jump" and turbine governor electro-hydraulic servo-positioning system are explained in the introduction. The electro-hydraulic servo-positioning system is also described, including the electro-hydraulic proportional valve. The analytical method of analyzing nonlinear resonance jump phenomenon is given. The simulation method is also described and the analysis of dead zone influence is illustrated.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekt / tema
0036010
0036046
0192010

Ustanove
Fakultet elektrotehnike i računarstva, Zagreb,
Brodarski institut d.o.o.