A comparative analysis of five chrome green pigments based on different spectroscopic (CROSBI ID 104212)
Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Desnica, Vladan ; Furić, Krešimir ; Hochleitner, B. ; Mantler, M.
engleski
A comparative analysis of five chrome green pigments based on different spectroscopic
A detailed study of five chrome-based green pigments belonging to a large pigment collection at the Academy of Fine Arts in Vienna, Austria has been performed. The samples were analyzed and compared using the two X-ray methods— X-ray fluorescence and X-ray diffraction, and the two optical methods— Raman spectroscopy and infrared spectroscopy. The composition differences between the similarly denoted samples of the collection were determined and the significant sensitivity differences of the investigated methods to specific compounds have been established. This relative discrepancy of the obtained results depending on the technique used proved once again the need of a combined use of the investigated methods.
X-ray fluorescence; X-ray diffraction; Raman spectroscopy; Fourier transform infrared spectroscopy; Chrome green
Rad je prezentiran na skupu 16th International Conference on X-ray Optics and Microanalysis, održanom od 02.–06.07.2001.g., Beč, Austrija.
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o izdanju
58 (4)
2003.
681-687
objavljeno
0584-8547
10.1016/S0584-8547(02)00283-5