Thermodyinamic aspects of dehumidifying drying
The method for minimization of unit heat consumption by the optimal selection of the air cooler parameters was performed. Energy consumption can be reduced by heat recuperation in condenser from 15 up to 20%. The using of a heat pump enables to save up to 70%.
Drying; energy savings; recuperation; heat pump