Napredna pretraga

Pregled bibliografske jedinice broj: 130351

ZONA NADZORA OKO RENGEN UREĐAJA ZA KONTROLU PUTNIČKE PRTLJAGE I POŠILJAKA


Prlić, Ivica; Radalj, Željko; Milković-Kraus, Sanja; Cerovac, Zdravko
ZONA NADZORA OKO RENGEN UREĐAJA ZA KONTROLU PUTNIČKE PRTLJAGE I POŠILJAKA // Zbornik radova petoga simpozija Hrvatskoga društva za zaštitu od zračenja s međunarodnim sudjelovanjem / Krajcar Bronić, Ines ; Miljanić, Saveta ; Obelić, Bogomil. (ur.).
Zagreb: HDZZ/CRPA, 2003. str. 197-202 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


Naslov
ZONA NADZORA OKO RENGEN UREĐAJA ZA KONTROLU PUTNIČKE PRTLJAGE I POŠILJAKA
(RADIATION PROTECTION CONTROL AREA AROUND BAGGAGE CONTROL X-RAY UNITS)

Autori
Prlić, Ivica ; Radalj, Željko ; Milković-Kraus, Sanja ; Cerovac, Zdravko

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Zbornik radova petoga simpozija Hrvatskoga društva za zaštitu od zračenja s međunarodnim sudjelovanjem / Krajcar Bronić, Ines ; Miljanić, Saveta ; Obelić, Bogomil. - Zagreb : HDZZ/CRPA, 2003, 197-202

Skup
Peti simpozij Hrvatskoga društva za zaštitu od zračenja s međunarodnim sudjelovanjem

Mjesto i datum
Stubičke Toplice, Hrvatska, 9-11.04.2003

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
N/A

Sažetak
The importance of prompt occupational dose reporting rises when dose is received within short-time interval or when the radiation source suffers any technical failures. Radiation exposure is to be recognized as a private/or group hazard of each person alone. Actual radiation quality of the source is to be taken into account. To optimize the radiological radiation protection Quality Control measurements of the source are done. We have developed digital dosemeters of type &#8220 ; ALARA OD2&#8221 ; for external dosimetry to be used for establishing the real pattern of occupational dose delivered to the workers or/and as the (Ort) professional environmental measuring station. We are using dosemeter to define the ccontrol areas and areas of concern - point (Ort) around the source. This upgrade to legal obligatory external (film badge) dosimetry will help us to ease defining the professional stuff and working places which are actually exposed to ionising radiation of concern and for which it is necessary to provide legally required, or even additional, occupational health care programme. This means the analysis of exposure situations for specific jobs near the x-ray equipment used for baggage control in the context of carrying out a detailed study for the optimisation of radiation protection. PC data readout from device forms a real time exposure dose rate pattern that proves that any worker or other employee working nearby the baggage x-ray unit is not obliged to undergo any legal occupational monitoring (dosimetry or health) hence the total dose per year will not exceed 1 mSv under the worst working conditions.

Izvorni jezik
Hrvatski

Znanstvena područja
Fizika, Elektrotehnika, Javno zdravstvo i zdravstvena zaštita



POVEZANOST RADA


Projekt / tema
0022001

Ustanove
Institut za medicinska istraživanja i medicinu rada, Zagreb