Determination of Stray Losses in Squirrel-cage Induction Motor Due to Converter Supply from Measurements in No-load Operation
Methods for determination of stray losses in converter-driven squirrel-cage induction motor at rated operation from results of no-load measurements are analysed. The computed and the measured values of losses are compared for the fundamental frequency of 50 Hz.