Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Digital dosimeter-&#8220 ; ALARA OD&#8221 ; - personal and environmental monitoring assembly (CROSBI ID 492483)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Prlić, Ivica ; Radalj, Željko ; Marović, Gordana ; Senčar, Jasminka ; Hršak, Hrvoje ; Vrtar, Mladen ; Cerovac, Zdravko Digital dosimeter-&#8220 ; ALARA OD&#8221 ; - personal and environmental monitoring assembly // Proceedings of the IRPA Regional Congress on Radiation Protection in Central Europe &#8220 ; Radiation Protection and Health&#8221 ; / Obelić, Bogomil ; Ranogajec-Komor, Maria ; Miljanić, Saveta et al. (ur.). Zagreb: Hrvatsko društvo za zaštitu od zračenja, 2002

Podaci o odgovornosti

Prlić, Ivica ; Radalj, Željko ; Marović, Gordana ; Senčar, Jasminka ; Hršak, Hrvoje ; Vrtar, Mladen ; Cerovac, Zdravko

engleski

Digital dosimeter-&#8220 ; ALARA OD&#8221 ; - personal and environmental monitoring assembly

The importance of prompt dose reporting rises when dose is received within short-time interval or when the radiation source suffers technical failures. New dosimetry concept, where radiation exposure is recognized as a private /or/ group hazard of each person involved in occupational ionizing sources handling, taking into account actual radiation quality of the source, based among other principles, on the principle of establishing the well defined controlled area is introduced. New digital dosimeter device, produced by ALARA Instruments Ltd., measures small occupational doses, including the background. Device is based on ionizing GM tube, a set of modern EEPROM memory chips and Li compound battery set. It operates in two modes and the measurements are continuously performed no matter which mode is on. First mode integrates the dose (including background). If user or dosimeter device enter the higher radiation field area second mode will separately start to measure the dose which is at least two times higher than the surrounding background. The level above which the higher field is considered has to be preprogrammed during the calibration of device. Level depends on the workplace type /or/ environmental conditions where the device will be used. Device is suitable ass well for the low level measurements and for the high radiation outputs. When used in the stronger fields, several devices can form a field monitoring system. Device is suitable for the various non-occupational purposes. With some telecommunication electronics and technical improvement, this device is usable as a point (Ort) environmental measuring station. Probe is sensitive to the background radiation and it is fast enough to record any change in normal environmental radiation field, send the data to the central station and raise alarm if necessary. We have built a prototype for environmental monitoring connectable to any kind of telecommunication net.

Digital dosemeter device; radiation exposure; occupational dose; environmantal monitoring

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

2002.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of the IRPA Regional Congress on Radiation Protection in Central Europe &#8220 ; Radiation Protection and Health&#8221 ;

Obelić, Bogomil ; Ranogajec-Komor, Maria ; Miljanić, Saveta ; Krajcar Bronić, Ines

Zagreb: Hrvatsko društvo za zaštitu od zračenja

Podaci o skupu

Nepoznat skup

poster

29.02.1904-29.02.2096

Povezanost rada

Fizika, Javno zdravstvo i zdravstvena zaštita