The influence of measurement methode on the initiation time measurement necessary for primer mixture initiation of electrical detonator (CROSBI ID 492369)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Zorić, Igor ; Kuhinek, Dalibor ; Dobrilović, Mario
engleski
The influence of measurement methode on the initiation time measurement necessary for primer mixture initiation of electrical detonator
This paper considers the differences in measurement of time necessary for primer mixture initiation of electrical detonator when measured with two different methods. First method is electro&#8211 ; optical where time measurement is electrically triggered but stopped by light of primer mixture flame. Second method is electrical and measures time of current flow through bridge wire. There was significant difference in attained results. Reasons, as well as the influence on application are discussed in this paper.
primer mixture; initiation time measurement; electric detonator
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
559-568-x.
2003.
objavljeno
Podaci o matičnoj publikaciji
Proceedings of the 6 th seminar New trends in research of energetic materials
Vagenknecht, Jirži
Pardubice: University of Pardubice
Podaci o skupu
6 th seminar New trends in research of energetic materials
poster
23.04.2003-25.04.2003
Pardubice, Češka Republika