Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Efficacy of Shock Wave-Enhanced Emission Photoacoustic Streaming (SWEEPS) in the Removal of Different Combinations of Sealers Used with Two Obturation Techniques: A Micro-CT Study. (CROSBI ID 325049)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Baraba, Anja ; Rajda, Marko ; Baršić, Gorana ; Jukić Krmek, Silvana ; Šnjarić, Damir ; Miletić, Ivana Efficacy of Shock Wave-Enhanced Emission Photoacoustic Streaming (SWEEPS) in the Removal of Different Combinations of Sealers Used with Two Obturation Techniques: A Micro-CT Study. // Materials, 16 (2023), 8; 3273, 10. doi: 10.3390/ma16083273

Podaci o odgovornosti

Baraba, Anja ; Rajda, Marko ; Baršić, Gorana ; Jukić Krmek, Silvana ; Šnjarić, Damir ; Miletić, Ivana

engleski

Efficacy of Shock Wave-Enhanced Emission Photoacoustic Streaming (SWEEPS) in the Removal of Different Combinations of Sealers Used with Two Obturation Techniques: A Micro-CT Study.

This study sought to evaluate the efficacy of SWEEPS in the removal of epoxy-resin-based and calcium-silicate-containing endodontic sealer combined with single-cone and carrier-based obturation techniques through a micro-CT analysis. Seventy-six single-rooted extracted human teeth with single root canal were instrumented with Reciproc instruments. Specimens were randomly divided into four groups (n = 19) according to the root canal filling material and obturation technique: (1) AH Plus sealer + Reciproc gutta-percha, (2) TotalFill BC sealer + TotalFill BC Points, (3) AH Plus sealer + Guttafusion obturator, and (4) MTA Fillapex + Guttafusion obturator. All specimens were re-treated one week later using Reciproc instruments. Following re-treatment, root canals were additionally irrigated using the Auto SWEEPS modality. The differences in the root canal filling remnants were analyzed by micro-CT scanning of each tooth after root canal obturation, after re-treatment, and after additional SWEEPS treatment. Statistical analysis was performed using an analysis of variance (p < 0.05). The additional treatment with SWEEPS significantly reduced the volume of the root canal filling materials in all experimental groups compared to the removal of root canal filling using only reciprocating instruments (p < 0.05). However, the root canal filling was not removed completely from any of the samples. SWEEPS can be used to enhance the removal of both epoxy-resin-based and calcium-silicate-containing sealers, in combination with single-cone and carrier-based obturation techniques.

SWEEPS ; calcium silicate sealer ; single-cone ; core-carrier ; re-treatment ; micro-CT analysis

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

16 (8)

2023.

3273

10

objavljeno

1996-1944

10.3390/ma16083273

Povezanost rada

nije evidentirano

Poveznice
Indeksiranost