Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Correlation of Shear Bond Strength and Degree of Conversion in Conventional and Self-Adhesive Systems Used in Orthodontic Bonding Procedures (CROSBI ID 324672)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Perković, Vjera ; Šimunović Aničić, Marina ; Lughi, Vanni ; Pozzan, Lucia ; Meštrović, Senka ; Turco, Gianluca Correlation of Shear Bond Strength and Degree of Conversion in Conventional and Self-Adhesive Systems Used in Orthodontic Bonding Procedures // Biomedicines, 11 (2023), 5; 1252, 11. doi: 10.3390/biomedicines11051252

Podaci o odgovornosti

Perković, Vjera ; Šimunović Aničić, Marina ; Lughi, Vanni ; Pozzan, Lucia ; Meštrović, Senka ; Turco, Gianluca

engleski

Correlation of Shear Bond Strength and Degree of Conversion in Conventional and Self-Adhesive Systems Used in Orthodontic Bonding Procedures

Self-adhesive systems have been proposed for the orthodontic bonding with the intention to reduce the traditional three-component system. (2) Methods: The sample consisted of 32 extracted intact permanent premolars randomly divided into two groups (n = 16). In Group I the metal brackets were bonded with Transbond XT Primer and Transbond XT Paste. In Group II the metal brackets were bonded with GC Ortho connect. The resin was polymerized for 20 s from two directions (mesial and occlusal) using a Bluephase light-curing unit. The shear bond strength (SBS) was measured using a universal testing machine. Immediately after SBS testing, Raman microspectrometry was performed for each sample to calculate the degree of conversion (DC). (3) Results: There was no statistically significant difference in the SBS between the two groups. A significantly higher DC (p < 0.001) value was recorded in Group II, in which the brackets were bonded with GC. Very weak or no correlation (0.01) was recorded between SBS and DC in Group I and moderate positive correlation was recorded in Group II (0.33). (4) Conclusions: No difference was found in SBS between the conventional and two-step systems used in orthodontics. The two-step system demonstrated higher DC compared to the conventional system. There is a very weak or moderate correlation between DC and SBS.

adhesive dentistry ; shear bond strength ; degree of conversion

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

11 (5)

2023.

1252

11

objavljeno

2227-9059

10.3390/biomedicines11051252

Povezanost rada

Dentalna medicina

Poveznice
Indeksiranost