Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

First measurement of the 94Nb(n,γ) cross section at the CERN n_TOF facility (CROSBI ID 734402)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

(n_TOF Collaboration) Balibrea-Correa, J. ; ... ; Bosnar, Damir ; ... ; Žugec, Petar First measurement of the 94Nb(n,γ) cross section at the CERN n_TOF facility // EPJ web of conferences, 279 / Freeman, S. ; Lederer-Woods, C. ; Manna, A. et al. (ur.). 2023. doi: 10.1051/epjconf/202327906004

Podaci o odgovornosti

Balibrea-Correa, J. ; ... ; Bosnar, Damir ; ... ; Žugec, Petar

n_TOF Collaboration

engleski

First measurement of the 94Nb(n,γ) cross section at the CERN n_TOF facility

One of the crucial ingredients for the improvement of stellar models is the accurate knowledge of neutron capture cross-sections for the different isotopes involved in the s-, r- and i- processes. These measurements can shed light on existing discrepancies between observed and predicted isotopic abundances and help to constrain the physical conditions where these reactions take place along different stages of stellar evolution. In the particular case of the radioactive 94Nb, the 94Nb(n, γ) cross-section could play a role in the determination of the s-process production of 94Mo in AGB stars, which presently cannot be reproduced by state-of-the-art stellar models. There are no previous 94Nb(n, γ) experimental data for the resolved and unresolved resonance regions mainly due to the difficulties in producing highquality samples and also due to limitations in conventional detection systems commonly used in time-of-flight experiments. Motivated by this situation, a first measurement of the 94Nb(n, γ) reaction was carried out at CERN n_TOF, thereby exploiting the high luminosity of the EAR2 area in combination with a new detection system of small-volume C6D6-detectors and a high quality 94Nb-sample. The latter was based on hyper-pure 93Nb material activated at the high-flux reactor of ILL-Grenoble. An innovative ring-configuration detection system in close geometry around the capture sample allowed us to significantly enhance the signal-to-background ratio. This set-up was supplemented with two conventional C6D6-detectors and a highresolution LaCl3(Ce)-detector, which will be employed for addressing reliably systematic effects and uncertainties. At the current status of the data analysis, 18 resonance in 94Nb+n have been observed for the first time in the neutron energy range from thermal up to 10 keV.

neutron capture, 94Nb, n_TOF, neutron time of flight

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

06004

2023.

objavljeno

10.1051/epjconf/202327906004

Podaci o matičnoj publikaciji

Freeman, S. ; Lederer-Woods, C. ; Manna, A. ; Mengoni, A.

2101-6275

2100-014X

Podaci o skupu

Nepoznat skup

predavanje

29.02.1904-29.02.2096

Povezanost rada

Fizika

Poveznice