Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Multidisciplinary Research of Thermal Springs Area in Topusko (Croatia) (CROSBI ID 323532)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Pavić, Mirja ; Kosović, Ivan ; Pola, Marco ; Urumović, Kosta ; Briški, Maja ; Borović, Staša Multidisciplinary Research of Thermal Springs Area in Topusko (Croatia) // Sustainability, 15 (2023), 6; ---. doi: 10.3390/su15065498

Podaci o odgovornosti

Pavić, Mirja ; Kosović, Ivan ; Pola, Marco ; Urumović, Kosta ; Briški, Maja ; Borović, Staša

engleski

Multidisciplinary Research of Thermal Springs Area in Topusko (Croatia)

Topusko is the second warmest natural thermal water spring area in Croatia, located at the southwest edge of the Pannonian Basin System. Due to favourable geothermal properties, these waters have been used for heating and health and recreational tourism since the 1980s. Thermal springs with temperatures up to 50 ◦C are the final part of an intermediate-scale hydrothermal system. However, systematic research on the Topusko spring area has not been conducted to lay the foundation for sustainable resource utilisation. Multidisciplinary research including the hydrogeochemical characterisation of naturally emerging thermal water, an electrical resistivity tomography (ERT) investigation conducted to reconstruct the subsurface geology, and hydrogeological parametrisation of the geothermal aquifer was carried out to refine the existing local conceptual model. The results show Ca-HCO3 facies of Topusko thermal waters, which get heated in a Mesozoic carbonate aquifer. The water equilibrium temperature in the geothermal aquifer is estimated to be 78 ◦C based on the SiO2-quartz geothermometer. The fault damage zone, which enables the upwelling of thermal water, was identified by ERT investigations. The transmissivity values of the aquifer derived from the results of step-drawdown tests range from 1.8 × 10−2 to 2.3 × 10−2 m2/s. Further multidisciplinary research is necessary to improve the existing conceptual model of the Topusko hydrothermal system.

thermal spring ; hydrogeochemical characteristics ; electrical resistivity tomography ; hydrogeological parameters ; hydrothermal system ; Croatia

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

15 (6)

2023.

---

objavljeno

2071-1050

10.3390/su15065498

Povezanost rada

Interdisciplinarne tehničke znanosti, Rudarstvo, nafta i geološko inženjerstvo

Poveznice
Indeksiranost