Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Reliability Assessment of Masonry Infilled RC Frame Building’s Earthquake Performance through Accidental Torsion Consideration (CROSBI ID 322288)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Burilo, Dalibor ; Markulak, Damir ; Dokšanović, Tihomir ; Penava, Davorin Reliability Assessment of Masonry Infilled RC Frame Building’s Earthquake Performance through Accidental Torsion Consideration // Civil engineering journal (Tehran), 9 (2023), 2; 483-496. doi: 10.28991/CEJ-2023-09-02-017

Podaci o odgovornosti

Burilo, Dalibor ; Markulak, Damir ; Dokšanović, Tihomir ; Penava, Davorin

engleski

Reliability Assessment of Masonry Infilled RC Frame Building’s Earthquake Performance through Accidental Torsion Consideration

Accidental torsional behaviour induced by horizontal loading is difficult to predict, being a complex phenomenon governed by many variables. This problem gains an additional dimension of complexity when nonlinear responses with imperfections need to be considered. Therefore, evaluation and understanding the influence of accidental torsion are fundamental in seismic reliability estimation. This study offers vital insights based on the results of a 1/2.5 scale three-story masonry infilled reinforced concrete frame building’s test on a shaking table. The building was tested under ten consecutive ground motions with increasing ag/g, recorded at Herzeg Novi station during the 1979-M6.9 Montenegro earthquake. The accidental eccentricity, considered a random variable, resulted from unsymmetrical masonry infill wall damage in an otherwise regular building. Its effect, in relation to that of other random (design) variables, was evaluated utilising weight factors and, in addition, assessed through various building code provisions and state-of-the-art research findings. The analysis revealed that the accidental eccentricity, as compared to other random variables considered, could, under certain conditions, reach values higher than those prescribed by the building codes. This unacceptable seismic reliability clearly warns that accidental torsion of masonry-infilled reinforced concrete frames in in-situ conditions must be considered even in regular buildings.

earthquake behavior ; masonry infill wall ; reinforced concrete frame ; accidental torsion ; reliability analysis

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

9 (2)

2023.

483-496

objavljeno

2676-6957

2476-3055

10.28991/CEJ-2023-09-02-017

Trošak objave rada u otvorenom pristupu

Povezanost rada

Građevinarstvo, Temeljne tehničke znanosti

Poveznice
Indeksiranost