Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Development of the New Sensor Based on Functionalized Carbon Nanomaterials for Promethazine Hydrochloride Determination (CROSBI ID 322109)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Samardžić, Mirela ; Peršić, Mateja ; Széchenyi, Aleksandar ; Jozanović, Marija ; Pukleš, Iva ; Budetić, Mateja Development of the New Sensor Based on Functionalized Carbon Nanomaterials for Promethazine Hydrochloride Determination // Sensors, 23 (2023), 5; 2641, 12. doi: 10.3390/s23052641

Podaci o odgovornosti

Samardžić, Mirela ; Peršić, Mateja ; Széchenyi, Aleksandar ; Jozanović, Marija ; Pukleš, Iva ; Budetić, Mateja

engleski

Development of the New Sensor Based on Functionalized Carbon Nanomaterials for Promethazine Hydrochloride Determination

Promethazine hydrochloride (PM) is a widely used drug so its determination is important. Solid-contact potentiometric sensors could be an appropriate solution for that purpose due to their analytical properties. The aim of this research was to develop solid-contact sensor for potentiometric determination of PM. It had a liquid membrane containing hybrid sensing material based on functionalized carbon nanomaterials and PM ions. The membrane composition for the new PM sensor was optimized by varying different membrane plasticizers and the content of the sensing material. The plasticizer was selected based on calculations of Hansen solubility parameters (HSP) and experimental data. The best analytical performances were obtained using a sensor with 2-nitrophenyl phenyl ether (NPPE) as the plasticizer and 4% of the sensing material. It had a Nernstian slope (59.4 mV/decade of activity), a wide working range (6.2 × 10−7 M–5.0 × 10−3 M), a low limit of detection (1.5 × 10−7 M), fast response time (6 s), low signal drift (−1.2 mV/hour), and good selectivity. The working pH range of the sensor was between 2 and 7. The new PM sensor was successfully used for accurate PM determination in a pure aqueous PM solution and pharmaceutical products. For that purpose, the Gran method and potentiometric titration were used.

promethazine hydrochloride ; solid-contact sensor ; potentiometry

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

23 (5)

2023.

2641

12

objavljeno

1424-8220

10.3390/s23052641

Povezanost rada

Kemija

Poveznice
Indeksiranost