Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Optimization of Ciprofloxacin Adsorption on Clinoptilolite-Based Adsorbents Using Response Surface Methodology (CROSBI ID 321615)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Kalebić, Barbara ; Bafti, Arijeta ; Cajner, Hrvoje ; Marciuš, Marijan ; Matijašić, Gordana ; Ćurković, Lidija Optimization of Ciprofloxacin Adsorption on Clinoptilolite-Based Adsorbents Using Response Surface Methodology // Nanomaterials, 13 (2023), 4; 740, 26. doi: 10.3390/nano13040740

Podaci o odgovornosti

Kalebić, Barbara ; Bafti, Arijeta ; Cajner, Hrvoje ; Marciuš, Marijan ; Matijašić, Gordana ; Ćurković, Lidija

engleski

Optimization of Ciprofloxacin Adsorption on Clinoptilolite-Based Adsorbents Using Response Surface Methodology

The adsorption of the antibiotic ciprofloxacin (CIP) from water solution by natural zeolite– clinoptilolite (CLI), magnetic clinoptilolite (MAG-CLI), and graphene oxide coated magnetic clinoptilolite (GO-MAG-CLI) was investigated. The novel approach of an environmentally friendly and cost-effective microwave-assisted method was applied for the magnetic composite synthesis. Detailed characterization of the prepared composites was achieved. In order to investigate the effect of the initial CIP concentration, pH, temperature, contact time, and type of adsorbent on the adsorption efficiency of CIP, and to obtain the optimal conditions for CIP removal, the response surface methodology central composite factorial design (RSM-CCF) was applied. The results obtained by the RSM-CCF showed that among the studied adsorbents, GO-MAG-CLI had the highest adsorption capacity for CIP, achieved for the initial concentration of 48.47 mg dm−3 at a pH of 5 and 24.78 °C after 19.20 min of contact time. The adsorption kinetics studied for the initial CIP concentration range of 15–50 mg dm−3 followed Lagergren’s pseudo-second-order model, and the Langmuir isotherm was the most suitable one to describe the CIP adsorption onto GO-MAG- CLI.

ciprofloxacin ; clinoptilolite ; magnetic nanoparticles ; graphene oxide ; response surface methodology

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

13 (4)

2023.

740

26

objavljeno

2079-4991

10.3390/nano13040740

Povezanost rada

Kemijsko inženjerstvo, Temeljne tehničke znanosti

Poveznice
Indeksiranost