Study of Cationic Surfactants Raw Materials for COVID-19 Disinfecting Formulations by Potentiometric Surfactant Sensor (CROSBI ID 321553)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Sakač, Nikola ; Madunić-Čačič, Dubravka ; Dean Marković, Dean ; Jozanović, Marija Study of Cationic Surfactants Raw Materials for COVID-19 Disinfecting Formulations by Potentiometric Surfactant Sensor // Sensors, 23 (2023), 4; 1-12. doi: 10.3390/s23042126

Podaci o odgovornosti

Sakač, Nikola ; Madunić-Čačič, Dubravka ; Dean Marković, Dean ; Jozanović, Marija

engleski

Study of Cationic Surfactants Raw Materials for COVID-19 Disinfecting Formulations by Potentiometric Surfactant Sensor

The behavior of a new 1, 3-dioctadecyl-1H-imidazol-3-ium tetraphenylborate (DODI-TPB) surfactant sensor was studied in single and complex mixtures of technical grade QACs—benzalkonium chloride (BAC), N, N-didecyl-N, N-dimethylammonium chloride (DDAC), and N, N-dioctyl-N, N-dimethylammonium chloride (DOAC) usually used in COVID-19 disinfecting agents formulations. The results obtained with the new DODI-TPB sensor were in good agreement with data measured by a 1, 3-dihexadecyl−1H-benzo[d]imidazol−3-ium-tetraphenylborate (DMI-TPB) surfactant sensor, as well as two-phase titration used as a reference method. The quantitative titrations of a two-component mixture of the cationic homologs (a) DDAC and DOAC ; and (b) BAC and DOAC showed that the new DODI-TPB surfactant sensor can clearly distinguish two separate mixture components in a single potentiometric titration curve with two characteristic inflexion points. The consumption of SDS (used as a titrant) in the end-point 1 (EP 1) corresponded to the content of DDAC (or BAC), whereas the consumption in the end-point 2 (EP 2) corresponded to the total content of both cationic surfactants in the mixture. DOAC content in both mixtures can be calculated from the difference of the titrant used to achieve EP1 and EP2. The addition of nonionic surfactants resulted in the signal change decrease from 333.2 mV (1:0 ; no nonionic surfactant added) to 243.0 mV (1:10, w/w). The sensor was successfully tested in ten two-component COVID-19 disinfecting formulations.

quaternary ammonium compounds ; QAC ; COVID-19 ; cationic surfactant ; disinfectant ; potentiometric sensor ; SARS-CoV-2

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

23 (4)

2023.

1-12

objavljeno

1424-8220

10.3390/s23042126

Povezanost rada

Interdisciplinarne prirodne znanosti, Kemija

Poveznice