Deformation Analysis of Advanced Pore Morphology Foam Elements using 4D X-ray Computed Micro- tomography (CROSBI ID 732150)
Prilog sa skupa u zborniku | prošireni sažetak izlaganja sa skupa | međunarodna recenzija
Podaci o odgovornosti
Kytyr, Daniel ; Zlamal, Petr ; Vopalensky, Michal ; Borovinsek, Matej ; Vesenjak, Matej ; Tomičević, Zvonimir
hrvatski
Deformation Analysis of Advanced Pore Morphology Foam Elements using 4D X-ray Computed Micro- tomography
This study applied in-situ 4D X-ray Computed Micro-tomography (XCT) experiments, where the advanced pore morphology (APM) foam elements were 3D scanned and compressed simultaneously for the first time. Such an approach enables a direct comparison between the mechanical response and the internal structure of the closed-cell foam and gives results on how the deformation of the internal structure affects the mechanical response of the aluminum alloy foam.
advanced pore morphology foam ; x-ray computed micro-tomography ; in-situ mechanical testing ; digital volume correlation
nije evidentirano
engleski
Deformation Analysis of Advanced Pore Morphology Foam Elements using 4D X-ray Computed Micro- tomography
nije evidentirano
advanced pore morphology foam ; x-ray computed micro-tomography ; in-situ mechanical testing ; digital volume correlation
nije evidentirano
Podaci o prilogu
179-180.
2022.
objavljeno
Podaci o matičnoj publikaciji
10th International Congress of Croatian Society of Mechanics - Book of Abstracts
Skozrit, Ivica ; Sorić, Jurica ; Tonković, Zdenko
Zagreb: Eurotisak
2623-6133
Podaci o skupu
10th International Congress of Croatian Society of Mechanic (ICCSM 2022)
predavanje
28.09.2022-30.09.2022
Pula, Hrvatska